Print

Balboa 120V Power Hook Up

Posted in Electrical

Balboa 120V Power Hook Up.

Electrical Hook Up Must Be Performed By A Licensed Electrician


NOTE: 120V GFCI Plug-in required if connecting to outlet.  GFCI breaker required if hard wiring.

For 120V power hook up dip switch 10 must be in the on position.

For 120V hook up the white 120V jumper wire must be installed from J11 to J32 (WHT AC to RED AC)

If J11 already has a wire installed unplug this wire and move it to J16. Also install the jumper wire from J11 to J32

Without the jumper wire the tub will not heat correctly.

Nordic-Hot-Tubs-Balboa-120V-Power-Hook-Up






















Install Line 1 onto the Hot Black labeled on the terminal block. Hot Red will remain empty.
For 120V power hook up dip switch 10 must be in the on position.
For 120V hook up the white 120V jumper wire must be installed from J11 to J32 (WHT AC to RED AC)
If J11 already has a wire installed unplug this wire and move it to J16 or any available spade in the WHT AC.

Without the jumper wire the tub will not heat correctly installed 120V.

Nordic-Hot-Tubs-Balboa-Heater-Schematics-120