Electrical
What is the power consumption on the Rendezvous Royal?
This tub has two primary pumps. And the power consumption is the same for both pumps.
But the amp draws are 7.4amps + 7.4amps = 14.8.
Total amp draw would be with the heater and both pumps on high speed.
This would be 7.4(pump 1 high) + 7.4(pump 2 high) + 23(heater) = 37.8amps.
This does not include any amp draw for ozonators, lights, or radios installed.
Power Cord Requirements
The wire gauge will have to meet the local code for a 50 Amp continuous draw circuit at the distance you are running the wire.
Nordic recommends 6 gauge - as long as it is big enough to meet the local codes requirements.
Any ground coating requirements will be determined by your local code.
It must be wired on a 50 Amp GFCI circuit and requires 4 wires.